Below is a list of the features of our open chassis single phase DC drives. Click on the model number for more information. An asterisk (*) means the option is available for that model.
Model Number | 300 | 370 | 400 | 800 | 1200 | 1600 | 400i | 1600i | 3200i | 3600XRi regen |
drive.web | * | * | * | * | ||||||
hp (110V unit) | 0.25 | 0.35 | 0.4 | 0.75 | 1 | 1.5 | 0.4 | 1.5 | 4 | 3.5 |
hp (230V unit) | 0.5 | 0.7 | 0.75 | 1 | 1.5 | 3 | .75 | 3 | 7.5 | 7.5 |
hp (460V unit) | (10) | (7.5) | ||||||||
Approvals | CE | CE | CSACE | CSACE | CSACE | CSACE | CSACE | CSACE | CSACE | CSACE |
Max Speed Set | * | * | * | * | * | * | * | * | * | * |
Min Speed Set | * | * | * | * | * | * | * | * | * | * |
Up Ramp Set | * | * | * | * | * | * | * | * | * | |
Down Ramp Set | * | * | * | * | * | * | * | * | ||
Max Current Set | * | * | * | * | * | * | * | * | * | |
IR Compensation | * | * | * | * | * | * | * | * | * | |
Stability Set | * | * | * | * | * | * | * | * | ||
Isolated Circuits | * | * | * | * | ||||||
Power Fuse | * | * | * | * | * | |||||
Control Fuses | * | * | * | * | ||||||
Auto 50/60 Hz | * | * | * | * | * | * | * | * | ||
150% Overload | * | * | * | * | * | * | * | * | ||
Electronic Contactor | * | * | * | * | * | * | * | * | ||
4 Speed Ranges | * | * | * | * | * | * | * | * | ||
4 Current Ranges | * | * | * | * | * | |||||
Power Up Inhibit | * | * | * | * | * | * | * | * | ||
50% Stall Select | * | * | * | * | * | * | * | * | ||
Precision Reference | * | * | * | * | * | * | * | * | ||
Precision Tach Input | * | * | * | * | * | * | * | * | ||
Model Number | 300 | 370 | 400 | 800 | 1200 | 1600 | 400i | 1600i | 3200i | 3600XRi regen |
Ramped Speed Input | * | * | * | * | * | * | * | * | * | |
Direct Speed Input | * | * | * | * | * | * | * | * | ||
Torque Input | * | * | * | * | * | * | * | * | ||
4-20mA Input | * | * | * | * | * | * | * | * | ||
Inverting Speed Input | * | * | * | * | * | * | * | * | ||
Aux Ramped Sp Input | * | * | * | * | ||||||
Current Loop Input | * | * | * | * | ||||||
Drive Run Input | * | * | * | * | * | * | * | * | * | |
Stall Relay | * | * | * | * | ||||||
Zero Speed Relay | * | * | * | * | ||||||
Configurable Relay | * | * | * | * | ||||||
Stall Output | * | * | * | * | * | * | * | * | ||
Zero Speed Output | * | * | * | * | * | * | * | * | ||
Speed Output | * | * | * | * | * | * | * | * | ||
Current Output | * | * | * | * | * | * | * | * | ||
Setpoint Ramp O/P | * | * | * | * | * | * | * | * | ||
Total Setpoint O/P | * | * | * | * | ||||||
12/24VDC Output | * | * | * | * | * | * | * | * |